PDF

FG4DT2

Thermocouple cable with silicone rubber insulation and braid of glass-fibre sheath

 

  1. Conductor
  2. Insulation
  3. Sheath

 

APPLICATION: Extension and compensating cables for thermocouples.

 

INSTALLATION: For fixed installation in dry environments at high temperature, in the absence of tensile stresses and forced displacements, laying in catenary with repeated cycles is not allowed.



FEATURES DESCRIPTION STANDARDS
Conductors: type T : +Cu -CuNi
type J : +Fe -CuNi
type E : +NiCr -CuNi
type K : +NiCr -NiAl
type W : +Fe -CuNi
type S and R : +Cu -CuNi
tipo B : +Cu -Cu
 
Insulation: silicone rubber  
Cores colour: see thermocouple table  
Sheath: braid of glass-fibre, oval shape  
Sheath colour: see thermocouple table  
Flame retardant:   CEI EN 60332-1-2
Halogen free: (< 0,5 mg/g - 0,5%) CEI EN 50267-2-1/2 - IEC 60754-1/2
Working temperatures: -60 °C ÷ +300 °C  
Bending radius: Ø x 7,5  

 

TYPE
N° x mm2
MEDIUM Ø OUTER
mm
MEDIUM WEIGHT
kg/km
PRODUCT CODE
2x0,5 4,6x2,5 25 B4702050(*)FV
2x0,8 5,2x3,0 33 B4702080(*)FV
2x1 5,4x3,1 39 B4702100(*)FV
2x1,3 6x3,2 46 B4702130(*)FV

(*) Add J for J-W-T-S calibration, K for K calibration

 

Berica Cavi S.p.A. reserves the right to change all information on the website without giving prior notice to customers and / or users