FR2OHR
Thermocouple cable with twisted cores, PVC insulated and Al/Pet screen
|
 |
- Conductor
- Insulation
- Drain wire
- Screen
- Sheath
|
|
APPLICATION: Extension and compensating cables for thermocouples.
INSTALLATION: For fixed and mobile installation in dry or wet environments, subjected to mechanical stresses of medium intensity however in the absence of tensile stresses and forced displacements, laying in catenary with repeated cycles is not allowed. The Al / PET tape screens the cable from electrostatic interference.
|
| FEATURES |
DESCRIPTION |
STANDARDS |
| Conductors: |
type T : +Cu -CuNi type J : +Fe -CuNi type E : +NiCr -CuNi type K : +NiCr -NiAl type W : +Fe -CuNi type S and R : +Cu -CuNi type B : +Cu -Cu |
|
| Insulation: |
PVC |
|
| Cores colour: |
see thermocouple table |
|
| Screen: |
Al/Pet tape |
|
| Drain wire: |
annealed red copper, diameter 0,5 mm |
|
| Sheath: |
PVC |
|
| Sheath colour: |
see thermocouple table |
|
| Flame retardant: |
|
CEI EN 60332-1-2 |
| Radiation resistant: |
8x107 kJ/kg |
|
| Working temperatures: |
-25 °C ÷ +105 °C |
|
| Bending radius: |
Ø x 7,5 |
|
|
|
TYPE N° x mm2 |
MEDIUM Ø OUTER mm |
MEDIUM WEIGHT kg/km |
PRODUCT CODE |
| 2x0,5 |
5,2 |
32 |
B4602050(*)SA |
| 2x0,8 |
6,2 |
45 |
B4602080(*)SA |
| 2x1 |
6,5 |
50 |
B4602100(*)SA |
| 2x1,3 |
7,2 |
60 |
B4602130(*)SA |
| 2x1,5 |
7,7 |
70 |
B4602150(*)SA |
|
(*) Add J for J-W-T-S calibration, K for K calibration
Berica Cavi Spa reserves the right to edit all the information on the website without providing prior notice to customers and / or users