PDF

FG4OHG4

Thermocouple cable with twisted cores, silicone rubber insulated and Al/Pet screen

 

  1. Conductor
  2. Insulation
  3. Drain wire
  4. Screen
  5. Sheath

 

APPLICATION: Extension and compensating cables for thermocouples.

 

INSTALLATION: For fixed and mobile installation in dry or wet environments at high temperature, subjected to low intensity mechanical stresses however in the absence of tensile stresses and forced displacements, laying in catenary with repeated cycles is not allowed. The Al / PET screens the cable from electrostatic interference.



FEATURES DESCRIPTION STANDARDS
Conductors: type T : +Cu -CuNi
type J : +Fe -CuNi
type E : +NiCr -CuNi
type K : +NiCr -NiAl
type W : +Fe -CuNi
type S and R : +Cu -CuNi
type B : +Cu -Cu
 
Insulation: silicone rubber  
Cores colour: see thermocouple table  
Screen: Al/Pet tape  
Drain wire: annealed red copper, diameter 0,5mm  
Sheath: silicone rubber  
Sheath colour: see thermocouple table  
Flame retardant:   CEI EN 60332-1-2
Radiation resistant: 2x107 kJ/kg  
Halogen free: (< 0,5 mg/g - 0,5%) CEI EN 50267-2-1/2 - IEC 60754-1/2
Working temperatures: -60 °C ÷ +180 °C  
Bending radius: Ø x 7,5  

 

TYPE
N° x mm2
MEDIUM Ø OUTER
mm
MEDIUM WEIGHT
kg/km
PRODUCT CODE
2x0,5 5,8 60 B4702050(*)SA
2x0,8 6,8 64 B4702080(*)SA
2x1 7,0 71 B4702100(*)SA
2x1,3 7,8 82 B4702130(*)SA
2x1,5 8,3 92 B4702150(*)SA

(*) Add J for J-W-T-S calibration, K for K calibration

 

Berica Cavi S.p.A. reserves the right to change all information on the website without giving prior notice to customers and / or users