FR2DR
Thermocouple cable with PVC insulation
|
 |
- Conductor
- Insulation
- Sheath
|
|
APPLICATION: Extension and compensating cables for thermocouples.
INSTALLATION: For fixed and mobile installation in dry or wet environments, subject to stresses of medium intensity however in the absence of tensile stresses and forced displacement, laying in catenary with repeated cycled is not allowed..
|
| FEATURES |
DESCRIPTION |
STANDARDS |
| Conductors: |
type T : +Cu -CuNi type J : +Fe -CuNi type E : +NiCr -CuNi type K : +NiCr -NiAl type W : +Fe -CuNi type S and R : +Cu -CuNi type B : +Cu -Cu |
|
| Insulation: |
PVC |
|
| Cores colour: |
see thermocouple table |
|
| Sheath: |
PVC, oval shape |
|
| Sheath colour: |
see thermocouple table |
|
| Flame retardant: |
|
CEI EN 60332-1-2 |
| Radiation resistant: |
8x107 kJ/kg |
|
| Working temperatures: |
-25 °C ÷ +105 °C |
|
| Bending radius: |
Ø x 7,5 |
|
|
|
TYPE N° x mm2 |
MEDIUM Ø OUTER mm |
MEDIUM WEIGHT kg/km |
PRODUCT CODE |
| 2x0,5 |
4,8x3,1 |
30 |
B4602050(*) |
| 2x0,8 |
5,8x3,6 |
41 |
B4602080(*) |
| 2x1 |
6,2x3,7 |
49 |
B4602100(*) |
| 2x1,3 |
6,8x4,1 |
60 |
B4602130(*) |
| 2x1,5 |
7,0x4,3 |
69 |
B4602150(*) |
|
(*) Add J for J-W-T-S calibration, K for K calibration