APPLICATION: Suitable for energy transport and the transmission of signals and controls where a certain level of protection
against electromagnetic interference is required. In the most risky environments in the event of a fire, such as
health facilities, entertainment venues and entertainment in general, gyms and sports centers. Hotels, guest
houses, motels, villages, tourist residences - hotels. Schools of every order, grade and type. Exhibitors and / or
retailers. Companies and offices with more than 300 people present; Libraries and archives, museums,
galleries, exhibitions and exhibitions. Buildings intended for civil use, with a fire height of more than 24 m.
(Average Risk)
INSTALLATION: For fixed indoor and outdoor installation even in wet environments. They can be installed on wall and metal
structures, on platforms, pipes, conduits and similar systems. Cable for direct and indirect burial.
|
| FEATURES | DESCRIPTION | STANDARDS |
| Conductors: |
annealed red copper cl.5 |
CEI EN 60228 (Tabella 9) |
| Insulation: |
LSZH compound, G16 quality |
CEI EN 50363 |
| Cores colour: |
|
CEI UNEL 00722 - HD 308 |
| Shield: |
braid of annealed red copper |
|
| Sheath: |
LSZH compound, M16 quality |
CEI EN 50363 |
| Sheath colour: |
green RAL 6018 |
|
| Halogen free: |
(< 0,5 mg/g - 0,5%) |
CEI EN 50267-2-1/2 - IEC 60754-1/2 |
| Low toxic gases emission: |
(toxicity index < 2%) |
CEI 20-37/4-0 |
| Current capacity: |
|
CEI UNEL 35024/1 - CEI UNEL 35026 |
| Rated voltage Uo/U: |
0,6/1 kV |
|
| Max. voltage: |
1,2 kV |
|
| Testing voltage: |
4 kV |
|
| Max working temperature: |
90 °C |
|
| Short-circuit temperature: |
250 °C |
|
| Min. installation temperature: |
0 °C |
|
| Bending radius: |
Ø x 8 |
|
| Max standard twisting (2x cable): |
≥ 10 twists/meter |
|
| REGULATION (UE) 305/2011 |
| System AVCP : |
1+ |
EN 50575:2014 + A1:2016 |
| Classification : |
Cca-s1a,d0,a1 |
UNI EN 13501-6 |
| Cca : |
Heat release and flame spread (FS ≤ 2m) |
EN 50399 |
| s1a : |
Smoke transmittance ≥ 80% (TSP ≤ 50 m2 and SPR ≤ 0.25 m2 / s) |
EN 50399 + EN 61034-2 |
| d0 : |
No flaming droplets |
EN 50399 |
| a1 : |
Gas acidity (Conductivity <2.5 ms / mm and pH> 4.3) |
EN 50267-2-3 |
|
Flame propagation (H ≤ 425 mm) |
EN 60332-1-2 |
| Printing: |
BERICA CAVI S.P.A. ITALY FG16OH2M16 0,6/1 kV Cca-s1a,d0,a1 CE Year/Lot - Type - 00000 m |
|
|
|
TYPE Nr x mm2 | MEDIUM Ø OUTER mm | MEDIUM WEIGHT kg/km | PRODUCT CODE |
| 2x1,5 | 8,9 | 95 | B13C02150 |
| 3G1,5 | 9,3 | 123 | B13C03150 |
| 4G1,5 | 10,3 | 149 | B13C04150 |
| 5G1,5 | 11,2 | 175 | B13C05150 |
| 7G1,5 | 12,2 | 226 | B13C07150 |
| 10G1,5 | 15,1 | 314 | B13C10150 |
| 12G1,5 | 16,0 | 367 | B13C12150 |
| 16G1,5 | 17,7 | 460 | B13C16150 |
| 19x1,5 | 18,6 | 527 | B13C19150 |
| 24G1,5 | 21,2 | 656 | B13C24150 |
| 2x2,5 | 9,9 | 123 | B13C02250 |
| 3G2,5 | 10,4 | 154 | B13C03250 |
| 4G2,5 | 11,3 | 194 | B13C04250 |
| 5G2,5 | 12,3 | 230 | B13C05250 |
| 7G2,5 | 13,6 | 304 | B13C07250 |
| 10G2,5 | 16,9 | 429 | B13C10250 |
| 12G2,5 | 17,7 | 494 | B13C12250 |
| 16G2,5 | 19,8 | 636 | B13C16250 |
| 24G2,5 | 23,7 | 913 | B13C24250 |
| 2x4 | 11,1 | 164 | B13C02400 |
| 3G4 | 11,7 | 212 | B13C03400 |
| 4G4 | 12,9 | 266 | B13C04400 |
| 5G4 | 14,2 | 328 | B13C05400 |
| 2x6 | 12,3 | 210 | B13C02600 |
| 3x6 | 13,3 | 289 | B13C03600 |
| 4G6 | 14,5 | 361 | B13C04600 |
| 5G6 | 16,0 | 442 | B13C05600 |
| 2x10 | 14,6 | 305 | B13C021000 |
| 4G10 | 17,1 | 525 | B13C041000 |
| 2x16 | 17,2 | 446 | B13C021600 |
| 3x16 | 18,2 | 606 | B13C031600 |
| 4G16 | 20,2 | 783 | B13C041600 |
|